Shenzhen Biokau Sci-tech Co.,ltd
Products
Contact Us
  • Contact Person : Ms. Samara Duan
  • Company Name : Shenzhen Biokau Sci-tech Co.,ltd
  • Tel : 86-0755-13724287324
  • Fax : --
  • Address : guangdong,Shenzhen,zhongshan
  • Country/Region : China
  • Zip : 518118

Transmissible Gastroenteritis virus (TGE) Antibody ELISA Test Kit

Transmissible Gastroenteritis virus (TGE) Antibody ELISA Test Kit
Product Detailed
Summary This kit use TGE virus solid phase antigen to detect specific antibody against TGE virus antigen, have high sensitivity, specificity, reproducibility, and is easy to operate quickly and used repeatedly. Reagents and contents 1.Coated microtiter strips 1 plate 7.Stopping solution 6ml 2.Conjugate solution 12ml 8.Negative control 800µl 3.10× Washing solution 50ml 9.Positive control 800µl 4.Substrate A solution 6ml 10.Serological plates 1 plate 5.Substrate B solution 6ml 11.Microplate Sealers 2 pieces 6.Sample dilution 50ml 12.Instruction sheet 1 copy Warning: Stopping solution irritates eyes and skin. Keep out of the reach of children. Upon contact with the eyes, rinse thoroughly with water and consult a doctor. Materials required but not provided 1.variable 0.5µl~10µl,10µl~100µland100µl~1000µl micropipettes 2.microtiter plate spectrophotometer(450nm) 3.distilled water or deionized water Test procedure 1 Diluting concentrated washing solution Dilute the concentrated washing solution with distilled water or deionized water at 1:10, e.g. add 270 ml distilled water in 30 ml concentrated washing solution, and mix thoroughly. 2 Sample preparation: Dilute the serum sample with sample dilution at 1:51, e.g. 4 μl serum + 200 μl sample dilution, mix thoroughly. 3 Adding samples and controls Leave well A1 as reagent blank. Pipette controls and samples as follows: 100 μl of negative control and positive control respectively, and 100 μl diluted samples each into remaining wells. Incubation at 37 ℃ for 30 minutes. Discard liquid of the wells and fill all wells with diluted washing solution, incubate for 1 minute and discard. Repeat washing procedure two more times as above. At the end of the washing step, carefully remove remaining fluid by tapping the strips on the tissue paper prior to the next step. 4 Adding conjugate solution Add 100 μl conjugate solution into all wells and incubate at 37 ℃ for 30 minutes. Discard liquid of the wells and wash 3 times as described in step 3. 5 Adding substrates Add 50 μl substrate A solution and B solution respectively, incubate at 37 ℃ for 10 minutes. Add 50 μl stopping solution into all wells. Before reading results with ELISA microtiter plate reader, set the reagent blank well A1 to zero . Measure the absorbance of all wells at 450 nm (reference wavelength: 620 nm). Results Judgment by microtiter plate reader Precondition of validity: absorbance value of negative control ≤ 0.1 and absorbance value of positive control ≥ 0.4 Cut-off value =0.2+ (Absorbance value of negative control), absorbance value of negative control should be regarded as 0.05 if it’s below 0.05. Interpretation of sample results Absorbance at 450nm ≥ cut-off: TGE antibody is positive Absorbance at 450nm < cut-off: TGE antibody is negative Storage instructions Store the kit at 2~8℃.Do not freeze any test kit components. Notes 1.store at 2-8℃, make the temperature of the kit return to room temperature before use. screw down the cap after use, don't mix caps between diffirent bottles and don't mix components between diffirent kits. 2. recommand to judge results with instruments to improve comparability of testing.


Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.